OKLAHOMA DEPARTMENT OF TRANSPORTATION
2019 ROADWAY DESIGN STANDARD DRAWINGS
Effective September 1, 2020
Revision History   Contact Rdy. Design
CODE: N=NEW, R=REVISED, D=DISCONTINUED
  SHEET NO. DESCRIPTION STANDARD REV. NO.
  Index Index of standards    
  R-1 EROSION CONTROL MAT ( EXCELSIOR MAT ) ECM1-4- 0
  R-2 EROSION CONTROL MAT ECM2-4- 0
  R-3 SOLID SLAB SODDING SSS-2- 0
  R-4 TEMPORARY SEDIMENT CONTROLS TSC1-4- 0
  R-5 TEMPORARY SEDIMENT CONTROLS TSC2-4- 0
  R-6 TEMPORARY SILT DIKE TSD-3- 0
  R-7 TEMPORARY FIBER LOG TFL-2- 0
  R-8 TEMPORARY ROCK FILTER DAMS TRFD-2- 0
R-11 ASPHALT SURFACING CONSTRUCTION DETAILS ASCD-6- 0
R-12 CONCRETE SURFACING CONSTRUCTION DETAILS CSCD-6- 0
  R-13 RESERVED    
R-14 JOINTS AND SEALERS - LONGITUDINAL, EXPANSION/ISOLATION
& CONTRACTION
LECS-5- 0
  R-15 LOAD TRANSFER UNITS FOR CONCRETE PAVEMENT JOINTS LTU-5- 0
  R-16 CONTINUOUSLY REINFORCED CONCRETE PAVMENT DETAILS CRCP1-4- 0
R-17 CONTINUOUSLY REINFORCED CONCRETE PAVMENT TERMINAL JOINTS CRCP2-4- 0
  R-18 PAVEMENT RECONSTRUCTION DETAILS PR-4- 0
R-19 PORTLAND CEMENT CONCRETE PAVEMENT REPAIR PCPR-4- 0
  R-20 PAVEMENT EDGE DRAIN PED-4- 0
  R-21 PAVEMENT SAFETY EDGE PSE-2- 0
R-22 WHEELCHAIR RAMPS WCR-4- 0
R-23 TACTILE WARNING DEVICES TWD-2- 0
R-24 PRECAST STANDARD MEDIAN DRAIN PSMD-2 0
R-25 PRECAST CURB INLET (DESIGNS 1, 2 AND 3) PCI-1 0
R-26 CULVERT END TREATMENT SINGLE PIPE INSTALLATION
1 TO 4 SAFETY SLOPE
CET4S-4- 0
R-27 CULVERT END TREATMENT SINGLE PIPE INSTALLATION
1 TO 6 SAFETY SLOPE
CET6S-4- 0
R-28 CULVERT END TREATMENT DOUBLE PIPE INSTALLATION
1 TO 4 SAFETY SLOPE
CET4D-4- 0
R-29 CULVERT END TREATMENT DOUBLE PIPE INSTALLATION
1 TO 6 SAFETY SLOPE
CET6D-4- 0
  R-30 PREFABRICATED CULVERT END SECTIONS PCES-5- 0
  R-31 SLOPED CONCRETE END SECTIONS SCES-4- 0
  R-32 CONCRETE DROP INLETS FOR R. C. BOXES ( 3' x 2' TO 6' x 6' ) CDIB-2- 0
  R-33 CONCRETE DROP INLETS FOR 30 DEG. SKEW R. C. BOXES ( 3' x 2' TO 6' x 6' ) CDIB30-2- 0
  R-34 CONCRETE DROP INLET FOR 18" TO 72" R. C. PIPES CDIP-2- 0
  R-35 CONCRETE DROP INLET FOR 30 DEG. SKEW 18" TO 72" R. C. PIPES CDIP30-2- 0
R-36 STANDARD MEDIAN DRAINS ( 18" TO 36" PIPES ) SMD-4- 0
  R-37 GRATED PIPE DROP INLET ( 18" TO 42" PIPE ) GPI-5- 0
  R-38 STORM SEWER CONSTRUCTION DETAILS SSCD-4- 0
  R-39 CURB INLETS CI-2- 0
  R-40 STORM SEWER INLET FRAMES ( CURB INLETS ) SSIF-5-0
  R-41 CAST IRON GRATES (CURB INLETS) CIG-4- 0
  R-42 MANHOLE FRAME AND COVER MFC-5- 0
R-43 MANHOLES AND JUNCTION BOXES MJB-4- 0
R-44 PRECAST ROUND MANHOLE PRM-1- 0
R-45 PRECAST SQUARE MANHOLE PSM-1- 0
R-46 PRECAST MANHOLE DETAILS PMD-1- 0
R-47 STANDARD PIPE INSTALLATION SPI-5- 0
R-48 FLEXIBLE PIPE INSTALLATION FPI-4- 0
R-49 STANDARD PIPE BEDDING SPB-2- 0
R-50 FILL HEIGHT TABLES ( METAL AND POLYPROPYLENE PIPES ) FHTMPP-2- 0
R-51 FILL HEIGHT TABLES ( CONCRETE PIPES ) FHTCP-4- 0
  R-52 STANDARD BOX INSTALLATION SBI-5- 0
R-53 PIPE UNDERDRAIN INSTALLATION PUD-4- 0
  R-55 DISCONTINUED (now in Traffic Standards)    
  R-56 DISCONTINUED (now in Traffic Standards)    
  R-57 DISCONTINUED (now in Traffic Standards)    
  R-58 DISCONTINUED (now in Traffic Standards)    
R-59 CONCRETE LONGITUDINAL BARRIER ( NCHRP 350 F-SHAPE ) CLB-2- 0
  R-62 MAILBOX INSTALLATION MI-4- 0
R-63 RURAL DRIVEWAY INSTALLATION RDI-4- 0
  R-64 PAVED DITCHES AND FLUMES DC-4- 0
  R-65 PAVEMENT DROP-OFF TREATMENTS PDT-2- 0
R-66 RIGHT-OF-WAY FENCE STYLE WWF ( WOVEN WIRE FENCE ) RWF1-3- 0
R-67 RIGHT-OF-WAY FENCE STYLE SWF ( STRAND WIRE FENCE ) RWF2-3- 0
R-68 RIGHT-OF-WAY FENCE STYLE CLF ( CHAIN LINK FENCE ) RWF3-3- 0
  R-69 RESERVED    
  R-70 SUPERELEVATION SUEL1-4- 0
  R-71 SUPERELEVATION TABLES (LOW SPEED URBAN STREETS) SUEL2-4- 0
  R-72 SUPERELEVATION TABLES (e max = 6 %) SUEL3-4- 0
  R-73 SUPERELEVATION TABLES (e max = 8 %) SUEL4-4- 0
2019 Roadway Standard drawings (low resolution, full set)